Premium core slitting machine manufacturer factory: When is it not allowed to adjust the tap changer of the transformer on-load voltage regulating device? The on-load voltage regulating device is a common accessory equipment of the transformer, which is used to adjust the transformation ratio when the transformer is running, so as to achieve the purpose of adjusting the output voltage. When using the on-load pressure regulator, the following points need to be paid attention to: It is not allowed to operate under live conditions: because the transformer is working under live conditions, the tap changer of the on-load voltage regulating device will have an arc when it is adjusted, so it is not allowed to operate the tap changer under live conditions. Frequent adjustments are not allowed: frequent adjustments to the tap changer of the on-load tap changer may cause damage to the tap changer or poor contact, thereby affecting the normal operation of the transformer. Discover more info at dry type transformer suppliers.

What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.

Several factors can affect power quality in transmission lines. These include: Load Characteristics: Non-linear loads can generate harmonics that distort the voltage and current waveforms, affecting the power quality. Transmission Line Length: Longer transmission lines have higher impedance, which can cause voltage drops and affect power quality. Faults on the System: Short circuits, ground faults, or equipment failures can lead to voltage sags, swells, or transients, impacting power quality. Switching Operations: The switching on/off of large loads or reactive power compensation devices can cause transient overvoltages that degrade power quality. Grid Interconnections: Interconnections between different power systems can introduce disturbances, affecting the power quality.

The materials that can be processed by longitudinal shear equipment include cold-rolled plate, stainless steel plate, aluminum plate, galvanized plate and color coated plate. However, for different materials, there are certain differences in the strength of blade materials, so as to obtain good cutting effect. Canwin slitting line supplier & manufacturer focus on the internal management and opens up the market.We continuously achieve development in the competition based on strong technical capability, high-quality products, and comprehensive and thoughtful services.

CANWIN adheres to the business policy of high -end manufacturing, intelligent equipment + intelligent factory, comprehensively improves the quality of products and the cutting speed and precision, accelerates the transformation of development mode, and promotes the upgrading of industrial structure In terms of new product development, the company relies on the “Guangdong university of technology provincial thin plate processing and cutting technology engineering center”as an innovation platform, continuously trains and introduces technological talents, and provides intellectual support for the company to enhance soft power and rapid development.

Canwin electrical equipment manufacturer provides diversified choices for customers. Distribution cabinet, power transformer equipment are available in a wide range of types and styles, in good quality and in reasonable price.Canwin collects scientific and rigorous of manufacturing and quality control management experience, in order to meet the different countries in different fields of capacitor products provide efficient, high-quality, fast service, so that the “Canwin”brand products win a good reputation all over the world.

Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.

The manufacturing technology and product quality of electrical steel plate is one of the important signs to measure the development level of special steel production and science and technology in a country. At present, the quantity, quality and specification of cold rolled electrical steel in China cannot meet the needs of energy (power) industry development, and there is a big gap between China and Japan in terms of production technology, equipment, management and scientific research.Canwin is one of the most professional silicon steel sheet suppliers in China, which has been specialized in silicon steel manufacturing for over 20 years.Contact us, we are the best choice. See additional info on https://www.canwindg.com/

Transformer application of aluminum foil to make dry type transformer has small volume, light weight, good insulation performance, flame retardant, no pollution, little partial discharge, moisture proof, stable and reliable operation, low noise, low maintenance cost advantages, in the high-rise building, underground facilities, business center, residential, hotels and humid coastal areas and other applications.Want to konw composition of aluminum foil, please contact Canwin, one of the best copper foil suppliers & manufacturers in China, specialized in aluminium copper foil and transformer copper foil for over 20 years. With the rapid development of laser machines technology and equipment, it is more and more widely used in various fields. At present, most hardware products still use argon arc welding and other welding methods in production and processing.

The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.

Impedance voltage (%): Short-circuit the secondary winding of the transformer and slowly increase the voltage on the primary winding. When the short-circuit current of the secondary winding equals the rated value, the voltage applied on the primary side is the impedance voltage. It is usually expressed as a percentage of the rated voltage. Phase number and frequency: Three-phase is represented by S, and single-phase is represented by D. The frequency f of China’s national standard is 50Hz.There are countries abroad with 60Hz (such as the United States).I. Temperature rise and cooling: The difference between the temperature of the transformer winding or upper oil layer and the temperature of the surrounding environment is called the temperature rise of the winding or upper oil layer. The limit value of the temperature rise of the oil-immersed transformer winding is 65K, and the temperature rise of the oil surface is 55K.There are also various cooling methods: oil-immersed self-cooling, forced air cooling, water cooling, tube type, sheet type, etc.